Development of a management model for the reduction of electricity consumption at “Majavita” farm

Authors

  • John Andersson Pinzón Pinzón Universidad Libre
  • Miguel Orlando Durán Rangel Universidad Libre
  • Angélica Juliana Mora Rangel Universidad Libre
  • Edgar Quintanilla Piña Universidad Libre

Keywords:

Electric power, Energy waste, Energy management, URE

Abstract

The energy consumption of Colombia is supplemented by systems based on the use of resources as follows: hydraulic 64%, thermal 38%, equipment smaller 4.8% and cogenerators 0.4%. In addition, the demand for electric power in Colombia, in 2012, reached 59.370GWh, with the weekend being the time when this resource is used the most, during the year 2015 the transactions for energy purchase and sale was $ 10.87 trillion having a cost of $ 120.72 KWh.

 

In the first stage of the project it was determined that there is a 32.5% excess electricity consumption in the Hacienda Majavita, partly due to unnecessarily electric elements connected to the electricity grid.

 

This research sought to identify the relationship between the consumer culture of the inhabitants of the Hacienda Majavita and the electric waste that is presented in it, as well, define the behavior of electric energy consumption and verify the compliance of RETIE in that place.

 

Through the direct observation of the place under study and the conduct of surveys to give a quantitative value to the consumer culture of the members of the university community was identified that in the halls and corridors of Majavita is where more energy is wasted.

Downloads

Download data is not yet available.

References

Begoña, D., & Quintanal, J. (2010). Bloque III?: TÉCNICAS DE INVESTIGACIÓN, 1-23. Retrieved from http://brayebran.aprenderapensar.net/files/2010/10/TECNICAS-DE-INVEST.pdf

Conchado, A., & Linares, P. (2008). Gestión activa de la demanda eléctrica doméstica?: beneficios y costes. V Congreso de La AEEE Vigo, 1-21.

Congreso de la República de Colombia. (2001). Contenido del Documento, 2003(Marzo 13), 1-18. Retrieved from http://www.alcaldiabogota.gov.co/sisjur/normas/Norma1.jsp?i=4449#

Congreso de la República de Colombia. (2014). May 2014, (May), 2014. Retrieved from http://www.upme.gov.co/Normatividad/Nacional/2014/LEY_1715_2014.pdf

Durán, M., Mora, A., & González, D. (2015). Articulo cientifico determinacion de la eficiencia en el consumo energetico de la hacienda majavita.

Durán, Miguel, Mora, Juliana, P. J. A. (2015). Determinacion de los factores intervinientes en el desperdicio del consumo electrico de la hacienda Majavita

Fallis, A. . (2013). No Title No Title. Journal of Chemical Information and Modeling, 53(9), 1689-1699. http://doi.org/10.1017/CBO9781107415324.004

Ferreira, M. A. M. A., Amaro, M., & Aguiar, M. (2009). A eficiência energética na reabilitação de edifícios. Faculdade de Ciências E Tecnologia, Universidade Nova de Lisboa.

Gram-Hanssen, K. (2010). Standby consumption in households analyzed with a practice theory approach. Journal of Industrial Ecology, 14, 150-165. http://doi.org/10.1111/j.1530-9290.2009.00194.x

Hanson, S., Seok, M., Lin, Y. S., Foo, Z., Kim, D., Lee, Y., … Blaauw Dr., D. (2009). A low-voltage processor for sensing applications with picowatt standby mode. In IEEE Journal of Solid-State Circuits (Vol. 44, pp. 1145-1155). http://doi.org/10.1109/JSSC.2009.2014205

I.P.E.M 56 Abraham Juarez. (2016). Variables de medida Estación Meteorológica. Retrieved from http://www.oni.escuelas.edu.ar/2008/CORDOBA/1324/trabajo/temperatura.html

ICONTEC. (2011). Iso 50001. Economic Outlook. Retrieved from http://www.iso.org/iso/iso_50001_energy-es.pdf

IDAE. (2011). Plan de Ahorro Eficiencia Energetica 2011-2020. IDAE.

J. Aponte, J. A. (2013). Proyección de Demanda de Energía Eléctrica en Colombia. Bogotá,D.C.,Colombia. Retrieved from http://www1.upme.gov.co/sites/default/files/proyeccion_demanda_ee_Abr_2013.pdf

José Vicéns, J. M. (2003). U N M O D E L O D E P R E V I S I Ó N D E L A D E M A N D A D E E N E R G Í A E L É C T R I C A?: T H O R I I, 1-52.

Lagunes Díaz, E. G., Beltrán Morales, L. F., Stoyan, S., & Ortega Rubio, A. (2011). Pasado, presente y futuro del consumo y generación de energía eléctrica en Baja California Sur: Planeación y optimización para el estado más árido y aislado de la república. In Hacia la sustentabilidad ambiental de la producción de energía en México (pp. 139-176).

Lebot, B., Meier, A., & Anglade, A. (2000). Global implications of standby power use. In The Proceedings of ACEEE Summer Study on Energy Efficiency in Buildings.

Lee, Y., Seok, M., Hanson, S., Blaauw, D., & Sylvester, D. (2008). Standby power reduction techniques for ultra-low power processors. IEEE European Solid-State Circuits Conference, 186-189. http://doi.org/10.1109/ESSCIRC.2008.4681823

Mcgarry, L. (2004). Standby power challenge. 2004 International IEEE Conference on the Asian Green Electronics (AGEC). Proceedings of. http://doi.org/10.1109/AGEC.2004.1290867

Ministerio de Ambiente y Desarrollo Sostenible. (2012). Resolucion_186_de_2012_- _Metas_Ambientales.pdf. Bogotá,D.C.,Colombia. Retrieved from https://www.minambiente.gov.co/images/AsuntosambientalesySectorialyUrbana/pdf/emisiones_atmosfericas_contaminantes/Insentivos/Resolucion_186_de_2012_-_Metas_Ambientales.pdf

Ministerio de Minas y Energía de Colombia. (2013). ENERGÍA ELÉCTRICA. Retrieved from http://www.minminas.gov.co/documents/10180/614096/4-Energia.pdf/97e512a3-3416-4f65-8ddad525aa616167

Osmel, M. S., & Gorrín, C. (2015). Indicadores de eficiencia energética en hoteles turísticos en Cuba Indicators for Energy Efficiency in Tourism Hotels in Cuba, 1-5.

Presidencia de La República de Colombia. (2003). Contenido del Documento, 2003(Marzo 13), 1-18. Retrieved from http://www.alcaldiabogota.gov.co/sisjur/normas/Norma1.jsp?i=11032

Presidencia de La República de Colombia. (2007). Contenido del Documento, 2003(Marzo 13), 1-18. Retrieved from http://www.alcaldiabogota.gov.co/sisjur/normas/Norma1.jsp?i=25479

Reineris Montero, Carlos Pérez, Ever Góngora, S. M. (2009). PREDICCIÓN DEL CONSUMO DE ELECTRICIDAD Y GAS LP EN UN HOTEL MEDIANTE REDES NEURONALES ARTIFICIALES. Medellin.

Thøgersen, J., & Grønhøj, A. (2010). Electricity saving in households-A social cognitive approach. Energy Policy, 38, 7732-7743. http://doi.org/10.1016/j.enpol.2010.08.025

Viebahn, P., Lechon, Y., Trieb, F., US Energy Information Administration, Universidad de Chile, Villanueva, J., … A, C. (2013). Modelo de estimación espacial del consumo eléctrico para la planificación de la expansión de sistemas de transmisión. Energy Policy, 14, 5-7. http://doi.org/10.2172/1011644

Vila, A., Sedano, M., López, A., & Ángel, J. (2013). Correlación lineal y análisis de regresión. Uoc, 1-21. Retrieved from www.UOC.edu

Downloads

Published

2019-12-06

Issue

Section

Artículos

How to Cite

Development of a management model for the reduction of electricity consumption at “Majavita” farm. (2019). El Centauro, 9(12), 83-90. https://revistas.unilibre.edu.co/index.php/centauro/article/view/5831

Most read articles by the same author(s)